This topic shows how to interface DHT22 (AM2302, RHT03) digital relative humidity and temperature sensor with PIC16F84A microcontroller, and how to simulate this interfacing using Proteus.
Note that for the simulation Proteus version should be 8.1 or higher. With these versions there is no need to install Proteus DHT22 library, it is included with the software, so don’t waste your time searching for dht22 library, dht22 Proteus library, dhtxx.mdf or dht22 module for Proteus, just use Proteus version 8.1 or higher.
About DHT22 (AM2302, RHT03) relative humidity and temperature sensor:
The DHT22(AM2302, RHT03) sensor comes in a single row 4-pin package and operates from 3.3 to 5.5V power supply. It can measure temperature from -40-80 °C with an accuracy of ±0.5°C and relative humidity ranging from 0-100% with an accuracy of ±2%. The sensor provides fully calibrated digital outputs for the two measurements. It has got its own proprietary 1-wire protocol, and therefore, the communication between the sensor and a microcontroller is not possible through a direct interface with any of its peripherals. The protocol must be implemented in the firmware of the MCU with precise timing required by the sensor.
The following timing diagrams describe the data transfer protocol between a MCU and the DHT22 sensor. The MCU initiates data transmission by issuing a “Start” signal. The MCU pin must be configured as output for this purpose. The MCU first pulls the data line low for at least 18 ms and then pulls it high for next 20-40 us before it releases it. Next, the sensor responds to the MCU “Start“ signal by pulling the line low for 80 us followed by a logic high signal that also lasts for 80 us. Remember that the MCU pin must be configured to input after finishing the “Start“ signal. Once detecting the response signal from the sensor, the MCU should be ready to receive data from the sensor. The sensor then sends 40 bits (5 bytes) of data continuously in the data line. Note that while transmitting bytes, the sensor sends the most significant bit first.
Data consists of decimal and integral parts. A complete data transmission is 40bit, and the sensor sends higher data bit first.
Data format: 16 bits RH data + 16 bits temperature data + 8bit check sum. If the data transmission is right, the check-sum should be the last 8bit of “MSB 8-bit RH data + LSB 8-bit RH data + MSB 8-bit temperature data + LSB 8-bit temperature data”.
The DHT22 is a digital sensor so it sends 1’s and 0’s, but it is very important to know how it sends the digital data. The figure below shows how the sensor sends its information:
Example: MCU has received 40 bits data from AM2302 as
0000 0010 1000 1100 0000 0001 0101 1111 1110 1110
16 bits RH data 16 bits T data check sum
Here we convert 16 bits RH data from binary system to decimal system,
0000 0010 1000 1100 → 652
Binary system Decimal system
RH=652/10=65.2%RH
Here we convert 16 bits T data from binary system to decimal system,
0000 0001 0101 1111 → 351
Binary system Decimal system
T=351/10=35.1℃
When highest bit of temperature is 1, it means the temperature is below 0 degree Celsius.
Example: 1000 0000 0110 0101, T= minus 10.1℃
16 bits T data
Sum=0000 0010+1000 1100+0000 0001+0101 1111=1110 1110
Check-sum=the last 8 bits of Sum=1110 1110
Interfacing PIC16F84A with DHT22(AM2302, RHT03) sensor circuit:
The following circuit schematic shows complete project circuit.
Interfacing PIC16F84A with DHT22 (AM2302, RHT03) sensor circuit:
The circuit is simple, there is the microcontroller PIC16F84A, DHT22 sensor and 1602 LCD to display humidity and temperature results.
Interfacing PIC16F84A with DHT22 (AM2302, RHT03) sensor CCS C code:
The interfacing code is written with CCS PIC C compiler PCWHD version 5.051.
If you want to understand the code please read the DHT22 datasheet.
Variables Time_out and k are used to test reading time to avoid wrong data reception or microcontroller hanging
Read more: PIC16F84A + DHT22(AM2302, RHT03) sensor Proteus simulation